{"id":1208,"date":"2025-10-27T00:39:33","date_gmt":"2025-10-26T21:09:33","guid":{"rendered":"https:\/\/kimiagene.com\/?p=1208"},"modified":"2025-11-08T18:33:11","modified_gmt":"2025-11-08T15:03:11","slug":"what-is-a-radiopharmaceutical-hood","status":"publish","type":"post","link":"https:\/\/kimiagene.com\/en\/what-is-a-radiopharmaceutical-hood\/","title":{"rendered":"What is a Radiopharmaceutical Hood?"},"content":{"rendered":"<p style=\"text-align: left;\" data-start=\"230\" data-end=\"716\">In recent years, the use of radioactive materials in medical sciences, pharmacy, and molecular research has grown significantly. The development of radiopharmaceuticals\u2014one of the advanced branches of nuclear pharmacy\u2014plays an important role in the diagnosis and treatment of diseases. However, working with radioactive materials requires strict safety principles and the use of standard protective equipment to prevent environmental contamination and radiation hazards for specialists.<\/p>\n<p style=\"text-align: left;\" data-start=\"718\" data-end=\"987\">One of the most important safety tools in this field is the radiopharmaceutical fume hood: a specialized device that, with radiation-resistant design and an advanced ventilation system, provides a safe environment for the synthesis and preparation of radioactive drugs.<\/p>\n<p style=\"text-align: left;\" data-start=\"989\" data-end=\"1253\">In this article, we intend to examine the radiopharmaceutical fume hood scientifically and technically-its main components, its differencesfrom other laboratory hoods, and the unique features of radiopharmaceutical hoods manufactured by <strong data-start=\"1227\" data-end=\"1252\"><a href=\"https:\/\/kimiagene.com\/\">Kimiagene Pajooh Pars<\/a>.<\/strong><\/p>\n<h2 style=\"text-align: left;\" data-start=\"1255\" data-end=\"1322\">What Is a Radiopharmaceutical Hood and What Is It Used For?<\/h2>\n<p style=\"text-align: left;\" data-start=\"1324\" data-end=\"1809\">In laboratory processes related to radioactive materials and radiopharmaceuticals, adhering to safety principles and controlling the spread of radioactive contamination is of vital importance. One of the primary pieces of equipment used to ensure this safety is the <strong data-start=\"1590\" data-end=\"1623\">Radiopharmaceutical Hood<\/strong>. This device, as a ventilation and personal protection system, prevents the release of vapors, aerosols, and particles contaminated with radioactive materials into the work environment.<\/p>\n<p style=\"text-align: left;\" data-start=\"1811\" data-end=\"2137\"><strong data-start=\"1811\" data-end=\"1836\">Kimiagene Pajooh Pars<\/strong>, with more than two decades of experience in designing and manufacturing specialized laboratory equipment, has brought the production of radiochemistry and radiopharmaceutical hoods into operation in accordance with international standards and the needs of the country\u2019s research and medical centers.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"2139\" data-end=\"2197\">Structure and Operation of the Radiopharmaceutical Hood<\/h2>\n<p style=\"text-align: left;\" data-start=\"2199\" data-end=\"2575\">A radiopharmaceutical hood functions similarly to a chemical fume hood but is designed with special measures to control radioactive emissions. This hood has a lead body or internal lead lining to absorb gamma and beta radiation, and its front window is made of lead glass of appropriate thickness so that, while providing user visibility, it prevents the passage of radiation.<\/p>\n<p style=\"text-align: left;\" data-start=\"2577\" data-end=\"2918\">Contaminated air inside the hood is filtered by <strong data-start=\"2625\" data-end=\"2633\">HEPA<\/strong> filters and <strong data-start=\"2646\" data-end=\"2666\">activated carbon<\/strong> filters and then exhausted to the outside. An intelligent ventilation system and corrosion-resistant fans ensure a uniform and safe airflow. All internal surfaces are made of <strong data-start=\"2842\" data-end=\"2865\">304 stainless steel<\/strong> so that decontamination can be performed completely.<\/p>\n<h2 style=\"text-align: center;\"><img decoding=\"async\" class=\"alignnone size-medium wp-image-1210\" src=\"https:\/\/kimiagene.com\/wp-content\/uploads\/2025\/10\/34d99facf00ef1fd91d2ef7e50327e75-300x158.jpg\" alt=\"\" width=\"300\" height=\"158\" srcset=\"https:\/\/kimiagene.com\/wp-content\/uploads\/2025\/10\/34d99facf00ef1fd91d2ef7e50327e75-300x158.jpg 300w, https:\/\/kimiagene.com\/wp-content\/uploads\/2025\/10\/34d99facf00ef1fd91d2ef7e50327e75-768x403.jpg 768w, https:\/\/kimiagene.com\/wp-content\/uploads\/2025\/10\/34d99facf00ef1fd91d2ef7e50327e75-600x315.jpg 600w, https:\/\/kimiagene.com\/wp-content\/uploads\/2025\/10\/34d99facf00ef1fd91d2ef7e50327e75.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/h2>\n<h2 style=\"text-align: left;\" data-start=\"2920\" data-end=\"3002\">Types of Radio Hoods (Radioactive \/ Radiochemistry \/ Radiopharmaceutical Hoods)<\/h2>\n<p style=\"text-align: left;\" data-start=\"3004\" data-end=\"3061\">Below we describe the types of radiopharmaceutical hoods:<\/p>\n<h3 style=\"text-align: left;\" data-start=\"3063\" data-end=\"3086\">Radiochemistry Hood<\/h3>\n<p style=\"text-align: left;\" data-start=\"3087\" data-end=\"3175\">Designed for performing chemical reactions with radioactive materials. Features include:<\/p>\n<ul style=\"text-align: left;\" data-start=\"3176\" data-end=\"3538\">\n<li data-start=\"3176\" data-end=\"3259\">\n<p data-start=\"3178\" data-end=\"3259\">All-steel body with lead lining for protection against gamma and beta radiation<\/p>\n<\/li>\n<li data-start=\"3260\" data-end=\"3336\">\n<p data-start=\"3262\" data-end=\"3336\">HEPA filter <strong data-start=\"3274\" data-end=\"3279\">+<\/strong> activated carbon filter to remove particles and vapors<\/p>\n<\/li>\n<li data-start=\"3337\" data-end=\"3379\">\n<p data-start=\"3339\" data-end=\"3379\">Exhaust airflow with negative pressure<\/p>\n<\/li>\n<li data-start=\"3380\" data-end=\"3538\">\n<p data-start=\"3382\" data-end=\"3538\">Viewing window made of lead glass<br data-start=\"3415\" data-end=\"3418\" \/><strong data-start=\"3418\" data-end=\"3434\">Application:<\/strong> synthesis of radiopharmaceuticals (e.g., FDG or Tc-99m) and stages of chemical combination of isotopes.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"text-align: left;\" data-start=\"3540\" data-end=\"3573\">Radiopharmaceutical Fume Hood<\/h3>\n<p style=\"text-align: left;\" data-start=\"3574\" data-end=\"3798\">This type is specifically for the <strong data-start=\"3608\" data-end=\"3654\">preparation, dilution, and final packaging<\/strong> of radioactive drugs. Compared to a radiochemistry hood, it has a more complex filtration system and <strong data-start=\"3756\" data-end=\"3787\">higher radiation protection<\/strong>. Features:<\/p>\n<ul style=\"text-align: left;\" data-start=\"3799\" data-end=\"4121\">\n<li data-start=\"3799\" data-end=\"3825\">\n<p data-start=\"3801\" data-end=\"3825\">Full lead-lined design<\/p>\n<\/li>\n<li data-start=\"3826\" data-end=\"3890\">\n<p data-start=\"3828\" data-end=\"3890\">Ability to control temperature and humidity in the workspace<\/p>\n<\/li>\n<li data-start=\"3891\" data-end=\"3955\">\n<p data-start=\"3893\" data-end=\"3955\">Multi-stage filtration (HEPA + activated carbon + prefilter)<\/p>\n<\/li>\n<li data-start=\"3956\" data-end=\"4121\">\n<p data-start=\"3958\" data-end=\"4121\">Display for radiation and internal pressure monitoring<br data-start=\"4012\" data-end=\"4015\" \/><strong data-start=\"4015\" data-end=\"4031\">Application:<\/strong> nuclear pharmacies, production and quality control (QC) centers for radiopharmaceuticals.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"text-align: left;\" data-start=\"4123\" data-end=\"4161\">Lead-Shielded Glove Box \/ Hot Cell<\/h3>\n<p style=\"text-align: left;\" data-start=\"4162\" data-end=\"4340\">The most advanced type of radio hood\u2014essentially a fully lead-shielded enclosed chamber with fixed gloves (glove ports). Typically used for highly radioactive isotopes. Features:<\/p>\n<ul style=\"text-align: left;\" data-start=\"4341\" data-end=\"4708\">\n<li data-start=\"4341\" data-end=\"4389\">\n<p data-start=\"4343\" data-end=\"4389\">Full lead body with <strong data-start=\"4363\" data-end=\"4377\">5 to 10 mm<\/strong> thickness<\/p>\n<\/li>\n<li data-start=\"4390\" data-end=\"4442\">\n<p data-start=\"4392\" data-end=\"4442\">Long fixed gloves to work without direct contact<\/p>\n<\/li>\n<li data-start=\"4443\" data-end=\"4481\">\n<p data-start=\"4445\" data-end=\"4481\">Thick lead glass (<strong data-start=\"4463\" data-end=\"4478\">10 to 15 mm<\/strong>)<\/p>\n<\/li>\n<li data-start=\"4482\" data-end=\"4554\">\n<p data-start=\"4484\" data-end=\"4554\">Fully filtered ventilation and exhaust to the central exhaust system<\/p>\n<\/li>\n<li data-start=\"4555\" data-end=\"4708\">\n<p data-start=\"4557\" data-end=\"4708\">Radiation monitor, alarm system, and interlock<br data-start=\"4603\" data-end=\"4606\" \/><strong data-start=\"4606\" data-end=\"4622\">Application:<\/strong> working with high-dose isotopes (e.g., I-131, Lu-177, Y-90) and radiotherapy centers.<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"text-align: left;\" data-start=\"4710\" data-end=\"4774\">Radioactive Transfer Hood (Transfer Hood \/ Pass-Through Box)<\/h3>\n<p style=\"text-align: left;\" data-start=\"4775\" data-end=\"5045\">Hoods for transferring radioactive materials between sections <strong data-start=\"4837\" data-end=\"4868\">without direct user contact<\/strong>. They have two-sided lead doors with an interlock system.<br data-start=\"4926\" data-end=\"4929\" \/><strong data-start=\"4929\" data-end=\"4945\">Application:<\/strong> connection between synthesis hood and QC hood, or transferring the sample to another test location.<\/p>\n<h3 style=\"text-align: left;\" data-start=\"5047\" data-end=\"5134\">Local Exhaust with Radioactive Filtration (Local Exhaust \/ Radioactive Filter Hood)<\/h3>\n<p style=\"text-align: left;\" data-start=\"5135\" data-end=\"5329\">A simpler, more compact model used in environments with <strong data-start=\"5191\" data-end=\"5212\">low radioactivity<\/strong>.<br data-start=\"5213\" data-end=\"5216\" \/><strong data-start=\"5216\" data-end=\"5232\">Application:<\/strong> educational work, laboratories with limited radioactive activity, or initial sample preparation.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"5331\" data-end=\"5372\">Summary Comparison of Radio Hood Types<\/h2>\n<ul style=\"text-align: left;\" data-start=\"5374\" data-end=\"6432\">\n<li data-start=\"5374\" data-end=\"5574\">\n<p data-start=\"5376\" data-end=\"5574\"><strong data-start=\"5376\" data-end=\"5385\">Type:<\/strong> Radiochemistry<br data-start=\"5400\" data-end=\"5403\" \/><strong data-start=\"5405\" data-end=\"5426\">Protection Level:<\/strong> Medium<br data-start=\"5433\" data-end=\"5436\" \/><strong data-start=\"5438\" data-end=\"5460\">Suitable Isotopes:<\/strong> Low-dose isotopes<br data-start=\"5478\" data-end=\"5481\" \/><strong data-start=\"5483\" data-end=\"5499\">Key Feature:<\/strong> Semi-lead design, HEPA filtration<br data-start=\"5533\" data-end=\"5536\" \/><strong data-start=\"5538\" data-end=\"5554\">Application:<\/strong> Synthesis reactions<\/p>\n<\/li>\n<li data-start=\"5576\" data-end=\"5776\">\n<p data-start=\"5578\" data-end=\"5776\"><strong data-start=\"5578\" data-end=\"5587\">Type:<\/strong> Radiopharmaceutical<br data-start=\"5607\" data-end=\"5610\" \/><strong data-start=\"5612\" data-end=\"5633\">Protection Level:<\/strong> High<br data-start=\"5638\" data-end=\"5641\" \/><strong data-start=\"5643\" data-end=\"5666\">Suitable Materials:<\/strong> Radiopharmaceuticals<br data-start=\"5687\" data-end=\"5690\" \/><strong data-start=\"5692\" data-end=\"5708\">Key Feature:<\/strong> Multi-stage filtration system<br data-start=\"5738\" data-end=\"5741\" \/><strong data-start=\"5743\" data-end=\"5759\">Application:<\/strong> Packaging and QC<\/p>\n<\/li>\n<li data-start=\"5778\" data-end=\"6031\">\n<p data-start=\"5780\" data-end=\"6031\"><strong data-start=\"5780\" data-end=\"5789\">Type:<\/strong> Lead-Isolated (Glove Box \/ Hot Cell)<br data-start=\"5826\" data-end=\"5829\" \/><strong data-start=\"5831\" data-end=\"5852\">Protection Level:<\/strong> Very High<br data-start=\"5862\" data-end=\"5865\" \/><strong data-start=\"5867\" data-end=\"5889\">Suitable Isotopes:<\/strong> Highly radioactive isotopes<br data-start=\"5917\" data-end=\"5920\" \/><strong data-start=\"5922\" data-end=\"5938\">Key Feature:<\/strong> Full lead body with fixed gloves<br data-start=\"5971\" data-end=\"5974\" \/><strong data-start=\"5976\" data-end=\"5992\">Application:<\/strong> Industrial production and radiotherapy<\/p>\n<\/li>\n<li data-start=\"6033\" data-end=\"6231\">\n<p data-start=\"6035\" data-end=\"6231\"><strong data-start=\"6035\" data-end=\"6044\">Type:<\/strong> Radioactive Transfer<br data-start=\"6065\" data-end=\"6068\" \/><strong data-start=\"6070\" data-end=\"6091\">Protection Level:<\/strong> Medium<br data-start=\"6098\" data-end=\"6101\" \/><strong data-start=\"6103\" data-end=\"6126\">Suitable Materials:<\/strong> Any type<br data-start=\"6135\" data-end=\"6138\" \/><strong data-start=\"6140\" data-end=\"6156\">Key Feature:<\/strong> Two-sided interlock system<br data-start=\"6183\" data-end=\"6186\" \/><strong data-start=\"6188\" data-end=\"6204\">Application:<\/strong> Safe transfer of materials<\/p>\n<\/li>\n<li data-start=\"6233\" data-end=\"6432\">\n<p data-start=\"6235\" data-end=\"6432\"><strong data-start=\"6235\" data-end=\"6244\">Type:<\/strong> Local Radioactive Exhaust<br data-start=\"6270\" data-end=\"6273\" \/><strong data-start=\"6275\" data-end=\"6296\">Protection Level:<\/strong> Low<br data-start=\"6300\" data-end=\"6303\" \/><strong data-start=\"6305\" data-end=\"6328\">Suitable Materials:<\/strong> Low-hazard materials<br data-start=\"6349\" data-end=\"6352\" \/><strong data-start=\"6354\" data-end=\"6370\">Key Feature:<\/strong> Lightweight, portable design<br data-start=\"6399\" data-end=\"6402\" \/><strong data-start=\"6404\" data-end=\"6420\">Application:<\/strong> Educational<\/p>\n<\/li>\n<\/ul>\n<h2 style=\"text-align: left;\" data-start=\"6434\" data-end=\"6513\">Comparison Table: Radiopharmaceutical Hood vs. Chemical and Biological Hoods<\/h2>\n<ul style=\"text-align: left;\" data-start=\"6515\" data-end=\"7366\">\n<li data-start=\"6515\" data-end=\"6756\">\n<p data-start=\"6517\" data-end=\"6538\"><strong data-start=\"6517\" data-end=\"6536\">Protection Type<\/strong><\/p>\n<ul data-start=\"6541\" data-end=\"6756\">\n<li data-start=\"6541\" data-end=\"6624\">\n<p data-start=\"6543\" data-end=\"6624\">Radiopharmaceutical Hood: against radioactive contamination and chemical vapors<\/p>\n<\/li>\n<li data-start=\"6627\" data-end=\"6684\">\n<p data-start=\"6629\" data-end=\"6684\">Chemical Fume Hood: against chemical vapors and gases<\/p>\n<\/li>\n<li data-start=\"6687\" data-end=\"6756\">\n<p data-start=\"6689\" data-end=\"6756\">Class II Biological Safety Cabinet: against microbial contamination<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6758\" data-end=\"6945\">\n<p data-start=\"6760\" data-end=\"6781\"><strong data-start=\"6760\" data-end=\"6779\">Body and Window<\/strong><\/p>\n<ul data-start=\"6784\" data-end=\"6945\">\n<li data-start=\"6784\" data-end=\"6846\">\n<p data-start=\"6786\" data-end=\"6846\">Radiopharmaceutical Hood: lead lining and thick lead glass<\/p>\n<\/li>\n<li data-start=\"6849\" data-end=\"6887\">\n<p data-start=\"6851\" data-end=\"6887\">Chemical Hood: ordinary steel body<\/p>\n<\/li>\n<li data-start=\"6890\" data-end=\"6945\">\n<p data-start=\"6892\" data-end=\"6945\">Class II BSC: HEPA filter present, but no lead lining<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6947\" data-end=\"7173\">\n<p data-start=\"6949\" data-end=\"6972\"><strong data-start=\"6949\" data-end=\"6970\">Filtration System<\/strong><\/p>\n<ul data-start=\"6975\" data-end=\"7173\">\n<li data-start=\"6975\" data-end=\"7045\">\n<p data-start=\"6977\" data-end=\"7045\">Radiopharmaceutical Hood: HEPA + activated carbon + direct exhaust<\/p>\n<\/li>\n<li data-start=\"7048\" data-end=\"7093\">\n<p data-start=\"7050\" data-end=\"7093\">Chemical Hood: simple exhaust ventilation<\/p>\n<\/li>\n<li data-start=\"7096\" data-end=\"7173\">\n<p data-start=\"7098\" data-end=\"7173\">Class II BSC: two HEPA filters for product\/personnel\/environment protection<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"7175\" data-end=\"7366\">\n<p data-start=\"7177\" data-end=\"7202\"><strong data-start=\"7177\" data-end=\"7200\">Primary Application<\/strong><\/p>\n<ul data-start=\"7205\" data-end=\"7366\">\n<li data-start=\"7205\" data-end=\"7273\">\n<p data-start=\"7207\" data-end=\"7273\">Radiopharmaceutical Hood: radiopharmaceuticals, nuclear medicine<\/p>\n<\/li>\n<li data-start=\"7276\" data-end=\"7321\">\n<p data-start=\"7278\" data-end=\"7321\">Chemical Hood: general chemical reactions<\/p>\n<\/li>\n<li data-start=\"7324\" data-end=\"7366\">\n<p data-start=\"7326\" data-end=\"7366\">Class II BSC: cell and microbial culture<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2 style=\"text-align: left;\" data-start=\"7368\" data-end=\"7447\">Features and Technical Specifications of Kimiagene Radiopharmaceutical Hoods<\/h2>\n<p style=\"text-align: left;\" data-start=\"7449\" data-end=\"7674\">Radiopharmaceutical hoods manufactured by <strong data-start=\"7491\" data-end=\"7516\">Kimiagene Pajooh Pars<\/strong> are designed in accordance with radiation safety requirements and the guidelines of the <strong data-start=\"7605\" data-end=\"7650\">Atomic Energy Organization of Iran (AEOI)<\/strong>. Main features include:<\/p>\n<ul style=\"text-align: left;\" data-start=\"7675\" data-end=\"8098\">\n<li data-start=\"7675\" data-end=\"7737\">\n<p data-start=\"7677\" data-end=\"7737\">Fully stainless-steel interior with protective lead lining<\/p>\n<\/li>\n<li data-start=\"7738\" data-end=\"7800\">\n<p data-start=\"7740\" data-end=\"7800\">Lead glass with adjustable thickness based on isotope type<\/p>\n<\/li>\n<li data-start=\"7801\" data-end=\"7855\">\n<p data-start=\"7803\" data-end=\"7855\">Double filtration system (HEPA + activated carbon)<\/p>\n<\/li>\n<li data-start=\"7856\" data-end=\"7923\">\n<p data-start=\"7858\" data-end=\"7923\">Digital controller for fan speed and internal negative pressure<\/p>\n<\/li>\n<li data-start=\"7924\" data-end=\"7986\">\n<p data-start=\"7926\" data-end=\"7986\">Radiation monitor and radiation contamination alarm system<\/p>\n<\/li>\n<li data-start=\"7987\" data-end=\"8031\">\n<p data-start=\"7989\" data-end=\"8031\">Ergonomic design with standard workspace<\/p>\n<\/li>\n<li data-start=\"8032\" data-end=\"8098\">\n<p data-start=\"8034\" data-end=\"8098\">Customizable dimensions and capacities based on laboratory needs<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"8100\" data-end=\"8220\">All models undergo air-leak testing, airflow uniformity evaluation, and radiation protection assessment before delivery.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"8222\" data-end=\"8291\">Applications of Radiopharmaceutical Hoods in Research and Industry<\/h2>\n<p style=\"text-align: left;\" data-start=\"8293\" data-end=\"8332\">These hoods are used widely, including:<\/p>\n<ul style=\"text-align: left;\" data-start=\"8333\" data-end=\"8646\">\n<li data-start=\"8333\" data-end=\"8417\">\n<p data-start=\"8335\" data-end=\"8417\">Synthesis and labeling units for radiopharmaceuticals (e.g., FDG, I-131, Tc-99m)<\/p>\n<\/li>\n<li data-start=\"8418\" data-end=\"8463\">\n<p data-start=\"8420\" data-end=\"8463\">Nuclear medicine departments of hospitals<\/p>\n<\/li>\n<li data-start=\"8464\" data-end=\"8513\">\n<p data-start=\"8466\" data-end=\"8513\">Quality control centers for radioactive drugs<\/p>\n<\/li>\n<li data-start=\"8514\" data-end=\"8579\">\n<p data-start=\"8516\" data-end=\"8579\">Radiotherapy research institutes and higher-education centers<\/p>\n<\/li>\n<li data-start=\"8580\" data-end=\"8646\">\n<p data-start=\"8582\" data-end=\"8646\">Pharmaceutical and research industries related to radiochemistry<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"8648\" data-end=\"8779\">Their use ensures user and environmental safety and prevents cross-contamination during critical stages of production and analysis.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"8781\" data-end=\"8881\">Standards and Design Requirements for Pharmaceutical Hoods (Especially Radiopharmaceutical Hoods)<\/h2>\n<p style=\"text-align: left;\" data-start=\"8883\" data-end=\"9211\">Whether for radioactive, chemical, or biological drugs, compliance with standards is one of the most important criteria for safety and performance approval of laboratory equipment. Below are technical, documented requirements for the design, manufacture, and testing of pharmaceutical hoods\u2014especially radiopharmaceutical hoods.<\/p>\n<h3 style=\"text-align: left;\" data-start=\"9213\" data-end=\"9233\">ISO 17873:2022<\/h3>\n<p style=\"text-align: left;\" data-start=\"9234\" data-end=\"9387\"><strong data-start=\"9234\" data-end=\"9312\">Performance and Safety Requirements for Containment Systems and Fume Hoods<\/strong> (laboratory ventilation and contamination-control enclosures). Key points:<\/p>\n<ul style=\"text-align: left;\" data-start=\"9388\" data-end=\"9734\">\n<li data-start=\"9388\" data-end=\"9442\">\n<p data-start=\"9390\" data-end=\"9442\">Defining permissible air-leak limits from the hood<\/p>\n<\/li>\n<li data-start=\"9443\" data-end=\"9505\">\n<p data-start=\"9445\" data-end=\"9505\">Design requirements to maintain internal negative pressure<\/p>\n<\/li>\n<li data-start=\"9506\" data-end=\"9577\">\n<p data-start=\"9508\" data-end=\"9577\">Methods for testing airflow uniformity (Velocity Distribution Test)<\/p>\n<\/li>\n<li data-start=\"9578\" data-end=\"9653\">\n<p data-start=\"9580\" data-end=\"9653\">Designing the exhaust path to prevent recirculation of contaminated air<\/p>\n<\/li>\n<li data-start=\"9654\" data-end=\"9734\">\n<p data-start=\"9656\" data-end=\"9734\">Evaluating permissible noise level, internal illumination, and vibration level<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"9736\" data-end=\"9844\">For radiopharmaceutical hoods, this standard is the main basis for ventilation and negative-pressure design.<\/p>\n<h3 style=\"text-align: left;\" data-start=\"9846\" data-end=\"9897\">EN 14175 (European Standard for Fume Cupboards)<\/h3>\n<p style=\"text-align: left;\" data-start=\"9898\" data-end=\"9907\">Includes:<\/p>\n<ul style=\"text-align: left;\" data-start=\"9908\" data-end=\"10165\">\n<li data-start=\"9908\" data-end=\"9933\">\n<p data-start=\"9910\" data-end=\"9933\">Gas-leak test methods<\/p>\n<\/li>\n<li data-start=\"9934\" data-end=\"9990\">\n<p data-start=\"9936\" data-end=\"9990\">Performance testing under various airflow conditions<\/p>\n<\/li>\n<li data-start=\"9991\" data-end=\"10042\">\n<p data-start=\"9993\" data-end=\"10042\">Evaluation of HEPA and activated carbon filters<\/p>\n<\/li>\n<li data-start=\"10043\" data-end=\"10106\">\n<p data-start=\"10045\" data-end=\"10106\">Standard for user distance from the hood sash\/front opening<\/p>\n<\/li>\n<li data-start=\"10107\" data-end=\"10165\">\n<p data-start=\"10109\" data-end=\"10165\">Specifications for automatic ventilation control systems<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"10167\" data-end=\"10294\">According to EN 14175, <strong data-start=\"10190\" data-end=\"10207\">face velocity<\/strong> at the hood opening should be <strong data-start=\"10238\" data-end=\"10256\">0.4 to 0.6 m\/s<\/strong> to balance safety and flow stability.<\/p>\n<h3 style=\"text-align: left;\" data-start=\"10296\" data-end=\"10351\">IAEA (International Atomic Energy Agency) Standards<\/h3>\n<p style=\"text-align: left;\" data-start=\"10352\" data-end=\"10506\">IAEA publishes guidelines and radiation-safety requirements for working with radioactive materials that are mandatory for radiopharmaceutical hood design:<\/p>\n<ul style=\"text-align: left;\" data-start=\"10507\" data-end=\"10933\">\n<li data-start=\"10507\" data-end=\"10596\">\n<p data-start=\"10509\" data-end=\"10596\"><strong data-start=\"10509\" data-end=\"10546\">IAEA Safety Standards GSR Part 3:<\/strong> radiation protection requirements in workplaces<\/p>\n<\/li>\n<li data-start=\"10597\" data-end=\"10709\">\n<p data-start=\"10599\" data-end=\"10709\"><strong data-start=\"10599\" data-end=\"10637\">IAEA Safety Reports Series No. 64:<\/strong> guidance on designing radiochemistry spaces and ventilation equipment<\/p>\n<\/li>\n<li data-start=\"10710\" data-end=\"10782\">\n<p data-start=\"10712\" data-end=\"10782\">Mandatory lead shielding with thickness proportional to isotope type<\/p>\n<\/li>\n<li data-start=\"10783\" data-end=\"10878\">\n<p data-start=\"10785\" data-end=\"10878\">Controlled exhaust path and the use of HEPA and activated carbon filters prior to discharge<\/p>\n<\/li>\n<li data-start=\"10879\" data-end=\"10933\">\n<p data-start=\"10881\" data-end=\"10933\">Built-in radiation monitoring and leak-alarm systems<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"10935\" data-end=\"11042\">These standards form the safety basis for products by reputable companies, including Kimiagene Pajooh Pars.<\/p>\n<h3 style=\"text-align: left;\" data-start=\"11044\" data-end=\"11100\">Atomic Energy Organization of Iran (AEOI) Guidelines<\/h3>\n<p style=\"text-align: left;\" data-start=\"11101\" data-end=\"11229\">In Iran, the design and manufacture of equipment related to radioactive materials must comply with AEOI regulations. Key points:<\/p>\n<ul style=\"text-align: left;\" data-start=\"11230\" data-end=\"11498\">\n<li data-start=\"11230\" data-end=\"11296\">\n<p data-start=\"11232\" data-end=\"11296\">Evaluating the <strong data-start=\"11247\" data-end=\"11267\">Shielding Factor<\/strong> of the body and lead glass<\/p>\n<\/li>\n<li data-start=\"11297\" data-end=\"11357\">\n<p data-start=\"11299\" data-end=\"11357\">Controlling the exhaust path and preventing air backflow<\/p>\n<\/li>\n<li data-start=\"11358\" data-end=\"11416\">\n<p data-start=\"11360\" data-end=\"11416\">Annual calibration requirements for radiation monitors<\/p>\n<\/li>\n<li data-start=\"11417\" data-end=\"11498\">\n<p data-start=\"11419\" data-end=\"11498\">Recording and maintaining documentation for radiation-leak and filtration tests<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"11500\" data-end=\"11627\">Domestic manufacturers such as <strong data-start=\"11531\" data-end=\"11556\">Kimiagene Pajooh Pars<\/strong> must obtain conformity approval from AEOI experts before installation.<\/p>\n<h3 style=\"text-align: left;\" data-start=\"11629\" data-end=\"11669\">ISO 14644 (Cleanroom Classification)<\/h3>\n<p style=\"text-align: left;\" data-start=\"11670\" data-end=\"11857\">This standard specifies indoor air cleanliness levels in terms of particulate concentration. Pharmaceutical hoods usually should operate at least at <strong data-start=\"11819\" data-end=\"11834\">ISO Class 7<\/strong> or better. This means:<\/p>\n<ul style=\"text-align: left;\" data-start=\"11858\" data-end=\"12002\">\n<li data-start=\"11858\" data-end=\"11929\">\n<p data-start=\"11860\" data-end=\"11929\">Particles larger than <strong data-start=\"11882\" data-end=\"11892\">0.5 \u03bcm<\/strong> must not exceed permissible limits<\/p>\n<\/li>\n<li data-start=\"11930\" data-end=\"12002\">\n<p data-start=\"11932\" data-end=\"12002\">HEPA filters must have <strong data-start=\"11955\" data-end=\"11966\">\u226599.97%<\/strong> efficiency for <strong data-start=\"11982\" data-end=\"11992\">0.3 \u03bcm<\/strong> particles<\/p>\n<\/li>\n<\/ul>\n<h3 style=\"text-align: left;\" data-start=\"12004\" data-end=\"12053\">Mechanical and Electrical Design Requirements<\/h3>\n<p style=\"text-align: left;\" data-start=\"12054\" data-end=\"12098\">Based on <strong data-start=\"12063\" data-end=\"12078\">IEC 61010-1<\/strong> and <strong data-start=\"12083\" data-end=\"12097\">ASTM E2352<\/strong>:<\/p>\n<ul style=\"text-align: left;\" data-start=\"12099\" data-end=\"12405\">\n<li data-start=\"12099\" data-end=\"12173\">\n<p data-start=\"12101\" data-end=\"12173\">The electrical system must be safe, spark-proof, and properly grounded<\/p>\n<\/li>\n<li data-start=\"12174\" data-end=\"12266\">\n<p data-start=\"12176\" data-end=\"12266\">Body and internal fittings must be made of corrosion-resistant, heat-resistant materials<\/p>\n<\/li>\n<li data-start=\"12267\" data-end=\"12321\">\n<p data-start=\"12269\" data-end=\"12321\">Lead glass must be resistant to mechanical impacts<\/p>\n<\/li>\n<li data-start=\"12322\" data-end=\"12405\">\n<p data-start=\"12324\" data-end=\"12405\"><strong data-start=\"12324\" data-end=\"12345\">Emergency exhaust<\/strong> must remain active during power loss or critical conditions<\/p>\n<\/li>\n<\/ul>\n<h2 style=\"text-align: left;\" data-start=\"12407\" data-end=\"12442\">Ergonomic Design and User Safety<\/h2>\n<p style=\"text-align: left;\" data-start=\"12444\" data-end=\"12804\">In the design of Kimiagene\u2019s radiopharmaceutical hoods, alongside technical and protective aspects, <strong data-start=\"12544\" data-end=\"12558\">ergonomics<\/strong> and user safety are carefully observed. Ergonomics means adapting equipment to human physical needs and limitations; therefore, these hoods are designed to allow users to work for long hours without fatigue, physical strain, or reduced accuracy.<\/p>\n<p style=\"text-align: left;\" data-start=\"12806\" data-end=\"13204\">The angle of the lead glass is adjusted to provide a direct, glare-free view for the operator, while the appropriate thickness ensures full radiation protection. The working height and control positions are selected based on human body dimensions to reduce repetitive and unnatural movements. Using LED lighting with standard intensity and angle allows precise observation of samples without glare.<\/p>\n<p style=\"text-align: left;\" data-start=\"13206\" data-end=\"13731\">Beyond user comfort, radiation-safety principles are also observed: appropriate distance between the operator and the radioactive source, uniform distribution of incoming and exhaust airflows, and radiation\/negative-pressure alarms\u2014all ensure safe, stable working conditions. Thus, ergonomic and safety-centered design in Kimiagene\u2019s radiopharmaceutical hoods not only increases user productivity but also minimizes radiation exposure risk and provides a safe, stable, user-friendly environment for radiochemistry activities.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"13733\" data-end=\"13798\">Installation and Commissioning of the Radiopharmaceutical Hood<\/h2>\n<p style=\"text-align: left;\" data-start=\"13800\" data-end=\"14351\">Installation and commissioning is a specialized process that must be performed by trained technical experts and in accordance with radiation-safety instructions. Before installation, the device location is evaluated for ventilation, power access, exhaust routing, and room pressure level to ensure stable airflow and complete removal of contaminated vapors. After positioning the device, connections for air discharge, filter pathways, and the central exhaust are set, and a <strong data-start=\"14275\" data-end=\"14301\">negative-pressure test<\/strong> is performed to evaluate ventilation performance.<\/p>\n<p style=\"text-align: left;\" data-start=\"14353\" data-end=\"14921\">Then, HEPA and activated carbon filters are installed in their designated housings and pressure drop is checked using a digital manometer. Electrical systems, internal lighting, and radiation alarms are tested individually to ensure correct operation. Finally, initial calibration of the radiation monitor, fan-speed adjustment, and air-leak testing are performed by the technical team. After final approval, the device is handed over in the presence of a radiation-protection specialist and complete user training and safety instructions are provided to the operator.<\/p>\n<p style=\"text-align: left;\" data-start=\"14923\" data-end=\"15120\">At <strong data-start=\"14926\" data-end=\"14951\">Kimiagene Pajooh Pars<\/strong>, this process is performed based on <strong data-start=\"14988\" data-end=\"14996\">IAEA<\/strong> standards and <strong data-start=\"15011\" data-end=\"15019\">AEOI<\/strong> guidelines to ensure the hood enters operation in a completely safe, stable, and reliable condition.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"15122\" data-end=\"15189\">Periodic Maintenance and Service of the Radiopharmaceutical Hood<\/h2>\n<p style=\"text-align: left;\" data-start=\"15191\" data-end=\"15801\">Periodic maintenance plays a decisive role in preserving safety, operational stability, and extending device lifespan. This process should be carried out at regular intervals\u2014usually every <strong data-start=\"15380\" data-end=\"15404\">six to twelve months<\/strong>\u2014by experienced technical teams under the supervision of the radiation-safety officer. During service, the status of the ventilation system, fan performance, internal negative pressure, and the efficiency of HEPA and activated carbon filters are evaluated. If filter efficiency is reduced, they are replaced with standard, certified units to prevent the return of contaminated vapors or particles.<\/p>\n<p style=\"text-align: left;\" data-start=\"15803\" data-end=\"16379\">Calibration of the radiation monitor, verification of alarm sensors, and air-leak testing of the body and internal connections are fixed parts of each service. If necessary, worn components\u2014including fans, gaskets, or control systems\u2014are replaced. After the technical steps, a complete performance report and test results are provided to the client. <strong data-start=\"16153\" data-end=\"16178\">Kimiagene Pajooh Pars<\/strong> offers on-site specialized services for repairs, filter replacement, calibration, and safety testing to ensure radiopharmaceutical hoods are maintained at the highest safety and operational standards.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"16381\" data-end=\"16424\">Safety Requirements and Hood Maintenance<\/h2>\n<p style=\"text-align: left;\" data-start=\"16426\" data-end=\"16620\">Using a radiopharmaceutical hood requires adherence to specific radiation standards. Operators must receive necessary safety training, and the hood must periodically undergo the following tests:<\/p>\n<ul style=\"text-align: left;\" data-start=\"16621\" data-end=\"16860\">\n<li data-start=\"16621\" data-end=\"16682\">\n<p data-start=\"16623\" data-end=\"16682\">Radiation-leak testing and contamination-level assessment<\/p>\n<\/li>\n<li data-start=\"16683\" data-end=\"16744\">\n<p data-start=\"16685\" data-end=\"16744\">Periodic replacement of HEPA and activated carbon filters<\/p>\n<\/li>\n<li data-start=\"16745\" data-end=\"16795\">\n<p data-start=\"16747\" data-end=\"16795\">Calibration of the radiation monitoring system<\/p>\n<\/li>\n<li data-start=\"16796\" data-end=\"16860\">\n<p data-start=\"16798\" data-end=\"16860\">Verification of fan performance and internal negative pressure<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"16862\" data-end=\"16955\">Following these requirements increases device lifespan and ensures complete workplace safety.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"16957\" data-end=\"17030\">How Do Iranian Radiopharmaceutical Hoods Differ from Imported Devices?<\/h2>\n<p style=\"text-align: left;\" data-start=\"17032\" data-end=\"17546\"><strong data-start=\"17032\" data-end=\"17047\">Technically<\/strong>, imported hoods are generally from leading global brands and are offered with advanced technologies and international certifications. However, in recent years, Iranian hoods, especially those produced by <strong data-start=\"17252\" data-end=\"17277\">Kimiagene Pajooh Pars<\/strong>, relying on <strong data-start=\"17290\" data-end=\"17298\">IAEA<\/strong> standards and <strong data-start=\"17313\" data-end=\"17321\">AEOI<\/strong> regulations, have achieved a high level of accuracy and safety. With robust design, precise ventilation, and standard <strong data-start=\"17440\" data-end=\"17448\">HEPA<\/strong> and <strong data-start=\"17453\" data-end=\"17473\">activated-carbon<\/strong> filters, these devices deliver performance equivalent to foreign models.<\/p>\n<p style=\"text-align: left;\" data-start=\"17548\" data-end=\"17948\">In terms of <strong data-start=\"17560\" data-end=\"17587\">service and maintenance<\/strong>, the difference between the two groups is significant. Imported devices often face delays and high costs for breakdowns or spare-part replacements, whereas Iranian models offer direct manufacturer support and on-site service, enabling repairs and calibration in the shortest possible time\u2014crucial for research centers or hospitals where downtime can be costly.<\/p>\n<p style=\"text-align: left;\" data-start=\"17950\" data-end=\"18446\">From an <strong data-start=\"17958\" data-end=\"17970\">economic<\/strong> perspective, Iranian hoods have a clear advantage. The initial purchase and installation cost is much lower than foreign brands, and spare-part supply and technical services are delivered more quickly and cheaply. In addition, the ability to <strong data-start=\"18213\" data-end=\"18226\">customize<\/strong> design, dimensions, and filter type based on each laboratory\u2019s needs in Kimiagene products offers more flexibility than imported models, making them an optimal choice for the country\u2019s scientific and industrial centers.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"18448\" data-end=\"18509\">Why Is Kimiagene\u2019s Radiopharmaceutical Hood a Good Option?<\/h2>\n<p style=\"text-align: left;\" data-start=\"18511\" data-end=\"18684\"><strong data-start=\"18511\" data-end=\"18536\">Kimiagene Pajooh Pars<\/strong>, leveraging specialized scientific and technical staff and long experience in designing laboratory safety equipment, offers distinctive advantages:<\/p>\n<ul style=\"text-align: left;\" data-start=\"18685\" data-end=\"18949\">\n<li data-start=\"18685\" data-end=\"18775\">\n<p data-start=\"18687\" data-end=\"18775\">Design and manufacture in accordance with international <strong data-start=\"18743\" data-end=\"18750\">ISO<\/strong> and <strong data-start=\"18755\" data-end=\"18763\">IAEA<\/strong> standards<\/p>\n<\/li>\n<li data-start=\"18776\" data-end=\"18840\">\n<p data-start=\"18778\" data-end=\"18840\">High-quality materials and full stainless-steel construction<\/p>\n<\/li>\n<li data-start=\"18841\" data-end=\"18901\">\n<p data-start=\"18843\" data-end=\"18901\">After-sales services, on-site installation, and training<\/p>\n<\/li>\n<li data-start=\"18902\" data-end=\"18949\">\n<p data-start=\"18904\" data-end=\"18949\">Technical support and rapid spare-part supply<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"18951\" data-end=\"19124\">Domestic production of this equipment, while reducing costs, also strengthens the country\u2019s scientific and industrial independence in the field of nuclear medical equipment.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"19126\" data-end=\"19205\">Video: Explanation About Kimiagene\u2019s Radiopharmaceutical Hood by Dr. Oskouei<\/h2>\n<p style=\"text-align: left;\" data-start=\"19206\" data-end=\"19242\"><code data-start=\"19206\" data-end=\"19242\"><iframe id='wp-aparat-6a1ca582c5eb9' src='https:\/\/www.aparat.com\/video\/video\/embed\/videohash\/cqiv5r6\/vt\/frame' width='100%' allowfullscreen='true' class='aparat-frame aparat-full-frame'><\/iframe><\/code><\/p>\n<h2 style=\"text-align: left;\" data-start=\"19244\" data-end=\"19335\">Further Explanation: On What Basis Is the Lead Thickness Used in This Device Determined?<\/h2>\n<p style=\"text-align: left;\" data-start=\"19336\" data-end=\"19372\"><code data-start=\"19336\" data-end=\"19372\"><iframe id='wp-aparat-6a1ca582c5f34' src='https:\/\/www.aparat.com\/video\/video\/embed\/videohash\/mra69z1\/vt\/frame' width='100%' allowfullscreen='true' class='aparat-frame aparat-full-frame'><\/iframe><\/code><\/p>\n<h2 style=\"text-align: left;\" data-start=\"19374\" data-end=\"19438\">This Video Is About the Applications of Radiopharmaceuticals:<\/h2>\n<p style=\"text-align: left;\" data-start=\"19439\" data-end=\"19475\"><code data-start=\"19439\" data-end=\"19475\"><iframe id='wp-aparat-6a1ca582c5f5a' src='https:\/\/www.aparat.com\/video\/video\/embed\/videohash\/ijg8icx\/vt\/frame' width='100%' allowfullscreen='true' class='aparat-frame aparat-full-frame'><\/iframe><\/code><\/p>\n<h2 style=\"text-align: left;\" data-start=\"19477\" data-end=\"19541\">What Has Happened as a Result of Producing This Hood in Iran?<\/h2>\n<p style=\"text-align: left;\" data-start=\"19542\" data-end=\"19578\"><code data-start=\"19542\" data-end=\"19578\"><iframe id='wp-aparat-6a1ca582c5f79' src='https:\/\/www.aparat.com\/video\/video\/embed\/videohash\/wlu832t\/vt\/frame' width='100%' allowfullscreen='true' class='aparat-frame aparat-full-frame'><\/iframe><\/code><\/p>\n<h2 style=\"text-align: left;\" data-start=\"19580\" data-end=\"19593\">Conclusion<\/h2>\n<p style=\"text-align: left;\" data-start=\"19595\" data-end=\"19969\">The radiopharmaceutical hood is a vital device for maintaining safety when working with radioactive materials; by controlling the release of contaminated vapors and particles, it ensures user health and environmental stability. The use of precise ventilation and multi-stage filtration makes this device an essential part of radiochemistry and nuclear-medicine laboratories.<\/p>\n<p style=\"text-align: left;\" data-start=\"19971\" data-end=\"20319\"><strong data-start=\"19971\" data-end=\"19996\">Kimiagene Pajooh Pars<\/strong>, relying on technical knowledge and years of experience in designing laboratory equipment, has succeeded in producing radiopharmaceutical hoods that compete with imported models in quality and safety. Ergonomic design, robust structure, and fast technical service are among the most important advantages of these products.<\/p>\n<p style=\"text-align: left;\" data-start=\"20321\" data-end=\"20633\">Overall, Kimiagene\u2019s radiopharmaceutical hood is a smart choice for centers seeking <strong data-start=\"20405\" data-end=\"20420\">high safety<\/strong>, <strong data-start=\"20422\" data-end=\"20446\">reliable performance<\/strong>, and <strong data-start=\"20452\" data-end=\"20477\">low maintenance costs<\/strong>. With adherence to international standards and local manufacturing, it provides a sustainable solution for the specialized laboratory needs of the country.<\/p>\n<h2 style=\"text-align: left;\" data-start=\"20635\" data-end=\"20696\">Frequently Asked Questions About Radiopharmaceutical Hoods<\/h2>\n<p style=\"text-align: left;\" data-start=\"20698\" data-end=\"21037\"><strong data-start=\"20698\" data-end=\"20765\">Does a radiopharmaceutical hood require an installation permit?<\/strong><br data-start=\"20765\" data-end=\"20768\" \/>Yes. Installation and operation must be supervised by a radiation-safety officer and approved by the <strong data-start=\"20869\" data-end=\"20907\">Atomic Energy Organization of Iran<\/strong>. After installation, radiation-leak testing and ventilation-performance verification are required to obtain the operating permit.<\/p>\n<p style=\"text-align: left;\" data-start=\"21039\" data-end=\"21344\"><strong data-start=\"21039\" data-end=\"21135\">What is the service life of HEPA and activated carbon filters in a radiopharmaceutical hood?<\/strong><br data-start=\"21135\" data-end=\"21138\" \/>Depending on usage level and type of radioactive materials, typically <strong data-start=\"21208\" data-end=\"21226\">6 to 12 months<\/strong>. With increased airflow resistance or reduced ventilation efficiency, filters must be replaced by the technical team.<\/p>\n<p style=\"text-align: left;\" data-start=\"21346\" data-end=\"21639\"><strong data-start=\"21346\" data-end=\"21412\">Is it possible to move or relocate a radiopharmaceutical hood?<\/strong><br data-start=\"21412\" data-end=\"21415\" \/>Due to the high weight of the lead body and the sensitivity of the ventilation system, relocation must only be carried out in coordination with the manufacturer and followed by retesting of performance and negative pressure.<\/p>\n<p style=\"text-align: left;\" data-start=\"21641\" data-end=\"21950\"><strong data-start=\"21641\" data-end=\"21739\">What is the difference between a radiopharmaceutical hood and a lead-isolated hood (Hot Cell)?<\/strong><br data-start=\"21739\" data-end=\"21742\" \/>A radiopharmaceutical hood is designed for low- to medium-dose radioactive drugs, whereas a lead-isolated hood (hot cell) is intended for high-dose isotopes and has a fully enclosed chamber with fixed gloves.<\/p>\n<p style=\"text-align: left;\" data-start=\"21952\" data-end=\"22217\"><strong data-start=\"21952\" data-end=\"22027\">Can a radiopharmaceutical hood be used for ordinary chemical materials?<\/strong><br data-start=\"22027\" data-end=\"22030\" \/>Technically possible, but <strong data-start=\"22056\" data-end=\"22075\">not recommended<\/strong>; the filters and exhaust path are designed to control radioactive contamination and may not be optimized for non-radioactive chemical vapors.<\/p>\n<p style=\"text-align: left;\" data-start=\"22219\" data-end=\"22450\"><strong data-start=\"22219\" data-end=\"22254\">How is user training performed?<\/strong><br data-start=\"22254\" data-end=\"22257\" \/>After installation, <strong data-start=\"22277\" data-end=\"22302\">Kimiagene Pajooh Pars<\/strong> provides complete training on operation, maintenance, filter replacement, and radiation safety. Written instructions are delivered with the device.<\/p>\n<p style=\"text-align: left;\" data-start=\"22452\" data-end=\"22733\" data-is-last-node=\"\" data-is-only-node=\"\"><strong data-start=\"22452\" data-end=\"22518\">What periodic tests should a radiopharmaceutical hood undergo?<\/strong><br data-start=\"22518\" data-end=\"22521\" \/>Periodic tests include <strong data-start=\"22544\" data-end=\"22570\">radiation-leak testing<\/strong>, <strong data-start=\"22572\" data-end=\"22601\">negative-pressure testing<\/strong>, <strong data-start=\"22603\" data-end=\"22629\">fan-performance checks<\/strong>, <strong data-start=\"22631\" data-end=\"22664\">airflow uniformity assessment<\/strong>, and <strong data-start=\"22670\" data-end=\"22703\">radiation-monitor calibration<\/strong>\u2014usually every <strong data-start=\"22718\" data-end=\"22732\">six months<\/strong>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In recent years, the use of radioactive materials in medical sciences, pharmacy, and molecular research has grown significantly. The development of radiopharmaceuticals\u2014one of the advanced branches of nuclear pharmacy\u2014plays an important role in the diagnosis and treatment of diseases. However, working with radioactive materials requires strict safety principles and the use of standard protective equipment [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":1215,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1208","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-1"],"_links":{"self":[{"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/posts\/1208","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/comments?post=1208"}],"version-history":[{"count":6,"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/posts\/1208\/revisions"}],"predecessor-version":[{"id":1261,"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/posts\/1208\/revisions\/1261"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/media\/1215"}],"wp:attachment":[{"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/media?parent=1208"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/categories?post=1208"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kimiagene.com\/en\/wp-json\/wp\/v2\/tags?post=1208"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}